  •  JRD212 DIN-rail Smart Prepaid Meter

JRD212 DIN-rail Smart Prepaid Meter

JIANGSU SUYUAN JERRY TECHNOLOGY CO., LTD    

Management innovation Product innovation satisfaction service


Welcome to inquire

Contact number:+86-527-81086617

Contact fax:0527-81086617

Contact email:Jerry_MKT@jssyjr. com



60 seconds manual response

Reply to technical advice within 30 minutes

Free 24-hour consultation service

Standard and Compliance                         

? IEC 62052-11: Electricity metering equipment (a.c.) – General requirements, tests and test conditions – Part 11: Metering equipment  

? IEC 62053-21: Electricity metering equipment (a.c.) – Particular requirements – Part 21: Static meter for active energy (classes 1 and 2)

? IEC 62055-41: Electricity metering – Payment systems – Part 41: Standard transfer specification (STS) - Application layer protocol for one-way token carrier systems

? DLMS/COSEM: Device Language Message Specification/Companion specification for Energy Metering

Product Features

? Non-volatile memory to store meter data without the use of a backup battery

? Support local/remote firmware upgrades.

? Split design, UIU with keypad installed in customer premise to monitor meter use

 

Main Functions

Measurements

? kWh (import, export and absolute)

? Maximum kW demand (import, export)

? Cumulative kW demand (import, export)

? Instantaneous value of voltage, current, phase angle, active power, power factor

? Current date and time

? Frequency

? Neutral line current measurement

Billing

? Automatic monthly billing reset on 00:00:00 of the 1st day in each month, configurable

? Remotely billing reset from AMI central system

? Up to 12 months of data in meter memory

Prepayment Functions

? Support online prepayment remotely from the AMI central system

? Low balance alert by audible alarm & LED alarm to remind user to top up

? Support emergency and friendly holiday mode

? STS/CTS mode switchable

? Prepaid/postpaid mode switchable

? A standard 12-key keypad on UIU with audio feedback upon key press

Load Profiles

? Record up to 100 days of 15-minute load profiles with 16 channels on a FIFO basis.

? Load profile interval configurable from 1-60 minutes

Tariff Functions

? Time of Use (TOU) measurement of import and export energies (kWh) and import and export demands (kW) (up to 4 tariffs, 12 seasons, 12 weeks, 16 switches, 100 special days)

? Internal battery to maintain clock and calendar

Power Quality

? Current reverse

? Over-voltage and under-voltage detection with a configurable time threshold

? Long and short outage detection with a configurable time threshold

? Over current detection with a configurable time threshold

? All power quality events will be recorded on meter memory

Anti-tamper

? Detection of terminal, external magnetic field, bypass etc.

? Show tamper alarm on the LED.

? All tamper events will be recorded on meter memory and sent to the AMI central system remotely

Disconnect/reconnect switch

? 2-pole internal latching relay supporting load limiting, load shedding, and prepayment function

? Remote disconnect/reconnect from AMI central system

? Scheduled disconnect/reconnect

Communication

? Full DLMS/COSEM and IEC 62056-21 compliance optical port

? MC171 for communication when there is no power

Internal PLC/RF module

Operating Voltage

230V

Current rating

5(100)A

Starting current

0.4% of Ib

Frequency

50Hz±5%

Accuracy Class

Active Energy: CL 1.0  1000 imp/kWh

Real-time Clock Accuracy

0.5s/Day

EMC

Electrostatic discharges(Contact discharges)

8kV

Electrostatic discharges(Air discharges)

15kV

Fast transient burst test

4kV

Surge immunity test

6kV

Electromagnetic RF field (80MHz to 2000MHz)

10V/m(with current), 30V/m(without current)

Diameter of terminal holes

10 mm

Environment

Temperature Range: -40 °C ~ +70 °C

Humidity: Up to 95%

Protective class

II

Degree of protection

IP54

Applicable scenarios:

? Industrial and commercial buildings.

? Small power distribution system.